Abstract:Semi-open vortex pump has one new kind of semi-open impeller. In order to study the cavitation performance, a numerical simulation was conducted to analyze internal flow field of semi-open vortex pump. One-phase model based on Reynolds time-averaged equations and RNG k-ε turbulence model was used. The distributions of pressure and velocity on blade surface were obtained. The bottom of semi-open impeller is crucial area for cavitation. Based on summarizing the detection of cavitation, the method combined sound and flow-head way was adopted for cavitation experiment. The results show that the semi-open vortex pump performance is steady and the semi-open impeller improve the cavitation performance. Under the same conditions, semi-open vortex pump performance is better than that of closed one. This provides basis of theoretical research and design for semi-open vortex pump.
[1]施卫东,董颖,马新华,等.流道截面形状对旋涡泵内部流动影响的数值模拟[J].农业工程学报,2005,21(3):21-23.Shi Weidong,Dong Ying,Ma Xinhua,et al.Numerical simulation of the effect of channel section shape on the inner flowing of vortex pump[J].Transactions of the CSAE,2005,21(3):21-23.(in Chinese)[2]Meakhail T,Park S O.An improved theory for regenerative pump performance[J].Power and Energy,2005,219(3):213-222.[3]Song J W,Engeda A,Chung M K.A modified theory for the flow mechanism in a regenerative flow pump[J].Power and Energy,2003,217(3):311-321.[4]Zhu Zuchao,Xie Peng,Ou Guofu,et al.Design and experimental analyses of small-flow high-head centrifugal-vortex pump for gas-liquid two-phase mixture[J].Chinese Journal of Chemical Engineering,2008,16(4):528-534.[5]Bajic B,Keller A.Spectrum normalization method in vibro-acoustical diagnostic measurements of hydroturbine cavitation[J].Journal of Fluids Engineering,1996,118:756-761.[6]Alfayez L,Mba D,Dyson G.The application of acoustic emission for detecting incipient cavitation and the best efficiency point of a 60 kW centrifugal pump:case study[J].NDT&E International,2005,38:354-358.[7]Yoshinobu T,Yoshiki Y,Yasukazu M.Observations of oscillating cavitation of an inducer[J].Journal of Fluids Engineering,1997,119:775-781.[8]Xavier E,Eduard E,Mohamed F,et al.Detection of cavitation in hydraulic turbines[J].Mechanical System and Signal Processing,2006,20:983-1007.