Abstract:Objective To investigate the effectiveness and safety of atrial fibrillation(AF) catheter ablation guided by magnetic navigation system(MNS) during learning curve. Methods In the sequence of operation time, 90 AF patients were divided into three groups: group A, B and C, each with 30 cases. After transseptal puncture, left atrial modeling as well as left and right pulmonary vein antrum isolation were performed with irrigated MNS catheter, and confirmed by “bulleye” software after isolation. The procedure time, X-ray exposure time and dose, instant success rate of pulmonary vein isolation and procedurerelated complications were recorded and analyzed. Holter recordings for once a month were done during 3 to 6 months follow up postoperatively. Results Ablation procedures were all performed successfully in 90 AF cases. The differences of procedure durations among the three groups were not statistically significant[(158.4±23.5) min, (150.4±22.5) min and (151.3±23.6) min,P>0.05]. The Xray exposure time and dose were significantly higher in group A than those in group B and C, but similar between the last two groups[(16.8±7.2) min, (8.2±2.6) min and (7.9±3.4) min, P<0.05 between group A and B; (583.7±460.3) mGy, (267.3±191.8) mGy and (225.0±121.0) mGy, P<0.05 between group A and B]. The instant success rate of pulmonary vein isolation was 96.2% in group A and 100% in group B and C. There was no statistically significant difference among the three groups(P>0.05). In perioperative period, 2 patients in group A experienced hemothorax, and 1 patient experienced groin hematoma. Meanwhile, 1 patient in group B developed lacunar cerebral infarct. No complication happened in group C. There was no statistically significant difference among the three groups(P>0.05). The success rates of operation were almost similar in the three groups during 3 to 6 months’ follow up postoperatively. Conclusion MNS guided AF catheter ablation proves to be safe and effective with a short learning curve.
郑杰, 李库林, 刘晓宇, 张常莹, 李晓燕, 李嘉萍, 郁志明, 王如兴. 磁导航系统指导下心房颤动导管消融学习曲线期间有效性和安全性分析[J]. 实用心电学杂志, 2016, 25(2): 96-100.
ZHENG Jie, LI Ku-Lin, LIU Xiao-Yu, ZHANG Chang-Ying, LI Xiao-Yan, LI Jia-Ping, YU Zhi-Ming, WANG Ru-Xing. Effectiveness and safety of atrial fibrillation catheter ablation guided by magnetic navigation system during learning curve. JOURNAL OF PRACTICAL ELECTROCARDIOLOGY, 2016, 25(2): 96-100.
[1] January CT, Wann LS, Alpert JS, et al. 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society[J]. J Am Coll Cardiol, 2014, 64(21):2305-2307.[2] 黄从新, 张澍, 马长生, 等. 心房颤动:目前的认识和治疗建议—2012[J]. 中华心律失常学杂志, 2012, 16(4):246-289. [3] Wann LS, Curtis AB, Ellenbogen KA, et al. Management of patients with atrial fibrillation (compilation of 2006 ACCF/AHA/ESC and 2011 ACCF/AHA/HRS recommendations): a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines[J]. Circulation, 2013, 127(18):1916-1926.[4] Bauernfeind T, Akca F, Schwagten B, et al. The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias[J]. Europace, 2011, 13(7):1015-1021.[5] 郑杰, 李库林, 郁志明, 等. 磁导航指导下心房颤动导管消融与床旁操作消融的临床比较研究[J]. 中华心律失常学杂志, 2014, 18(6):425-429. [6] 王如兴. 磁导航指导下心律失常的导管消融治疗[J]. 江苏实用心电学杂志, 2013, 22(4):742-747.[7] Choi MS, Oh YS, Jang SW, et al. Comparison of magnetic navigation system and conventional method in catheter ablation of atrial fibrillation: is magnetic navigation system is more effective and safer than conventional method?[J]. Korean Circ J, 2011, 41(5):248-252.[8] Shurrab M, Danon A, Lashevsky I, et al. Robotically assisted ablation of atrial fibrillation: a systematic review and metaanalysis[J]. Int J Cardiol, 2013,169(3):157-165.[9] Xu D, Yang B, Shan Q, et al. Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias[J]. J Interv Card Electrophysiol, 2009, 25(3):171-174.[10] Li C, Tang L, Yang Z, et al. Integration of dual source computed tomography with magnetic navigation system for percutaneous coronary intervention: a feasibility study[J]. Catheter Cardiovasc Interv, 2011, 78(7):1108-1115.[11] MalcolmeLawes L, Kanagaratnam P. Robotic navigation and ablation[J]. Minerva Cardioangiol, 2010, 58(6):691-699. [12] Duriez C,Cotin S,Lenoir J,et al.New approaches to catheter navigation for interventional radiology simulation[J].Comput Aided Surg, 2006, 11(6):300-308.[13] 张建军, 杨新春. 电生理检查及射频导管消融术中常见的设备故障及处理[J]. 中华心律失常学杂志, 2004, 8(6):390-391.