Abstract:According to the hydraulic model test of the urban pumping station which combined sewage with storm water, the inlet flow patterns and the influence of the inlet flow patterns on pump performance of the pumping station are studied, and some measures to ameliorate flow patterns are adopted. The result shows that the flow patterns and pump performance are improved, and the efficiency of the pump and the pumping station are enhanced greatly.
冯建刚;徐辉;陈毓陵;何逢标. 泵站圆形进水池进水流态及水泵性能研究[J]. 排灌机械工程学报, 2003, 21(5): 8-10.