Abstract:Model test is a main method to verify and modify the intake design of a pumping station, which is popularly used in the word. Up to now, there is no test standard for model test of intake design in our country. Integrative concept of pump intake design is briefly discussed, and based on"American National Standard for Pump Intake Design"(ANSI/HI 9.8-1998 ), the test purpose, main concept, test principle, measurement method, test scheme and evaluation of test results are illustrated.
陆林广;奚斌;左滨. 水泵进水设计模型试验方法[J]. 排灌机械工程学报, 2003, 21(5): 4-7.
LU Lin-guang, XI Bing, ZUO Bin. Research Method of Intake Hydraulic Design Model Test. Journal of Drainage and Irrigation Machinery Engin, 2003, 21(5): 4-7.
[1] .American National Standard for Pump Intake Design[Z].ANSI/HI 9.8,1998:22-28[2] 左东启.模型试验的理论和方法[M].北京:水利电力出版社,1984:53-55[3] 徐辉,段志强,于永海.泵站有压前池流态改善措施的研究[J].排灌机械,2003,21(4):13-16