Experiment on corrosion detection of load-bearing steel strand based on magnetic flux leakage signal
1. China Merchants Chongqing Communications Research & Design Institute Co.,Ltd.,Chongqing 400067,China; 2. School of Public Administration,Chongqing Finance and Economics College,Chongqing 401320,China; 3. College of Civil Engineering,Chongqing Jiaotong University,Chongqing 400074,China; 4. Guangzhou Municipal Engineering Testing Co.,Ltd.,Guangzhou,Guangdong 510520,China
Abstract:To detect the corrosion of load-bearing steel strand, the magnetic memory technology was introduced. Through the corrosion detection test of load-bearing steel strand, the magnetic flux leakage signal of steel strand was analyzed, and the corrosion detection criterion of load-bearing steel strand was constructed based on magnetic flux leakage signal. The results show that with the increasing of corrosion degree, the magnetic flux leakage signal of loaded steel strand is increased, and the tangential component of magnetic induction intensity meets at one point at both ends of the corrosion area with the maximum value in the middle of corrosion. The normal component of magnetic induction intensity has the reverse maximum and minimum values at both ends of the corrosion, which illuminates that the corrosion position and range of steel strand can be determined qualitatively. The relationships among the dimensioned peak value of tangential/normal component of magnetic induction intensity of magnetic flux leakage signal of load-bearing steel strand corrosion, the corrosion degree and the tensile force can be further analyzed. The relationships are distributed in Boltzmann function, which means that the corrosion degree and tensile force of steel strand can be determined quantitatively.
LAN C M,REN D L,XU Y,et al. Fatigue property assessment of parallel wire stay cable II: fatigue life model for stay cable [J]. Journal of Civil Engineering Journal,2017,50 (7): 69-77. (in Chinese)
ZHOU J T,ZHANG S H,ZHANG H,et al. Magnetic flux leakage signal analysis of corroded reinforcing bar in concrete [J]. Journal of Jiangsu University (Natural Science Edition),2019,40 (3): 355-359. (in Chinese)
MA H X,ZHOU J T,ZHAO R Q,et al. Non-destructive testing of steel bar stress based on metal magnetic memory technology [J]. Journal of Jiangsu University (Natural Science Edition),2018,39 (3): 349-354. (in Chinese)
[6]
XIA R C,ZHOU J T,HONG Z,et al. Quantitative study on corrosion of steel strands based on self-magnetic flux leakage[J]. Sensors,2018,18(5):1396.
[7]
ZHANG H,LIAO L,ZHAO R Q,et al. A new judging criterion for corrosion testing of reinforced concrete based on self-magnetic flux leakage[J]. International Journal of Applied Electromagnetics and Mechanics,2017,54(1):123-130.
[8]
QU Y H,ZHANG H,ZHAO R Q,et al. Research on the method of predicting corrosion width of cables based on the spontaneous magnetic flux leakage[J]. Mate-rials,2019,12(13):2154.
[9]
XIA R C,ZHOU J T,ZHANG H,et al. Experimental study on corrosion of unstressed steel strand based on metal magnetic memory[J]. KSCE Journal of Civil Engineering,doi:10.1007/s12205-019-0715-9.
ZHOU J T,ZHAO Y Y,HE Q,et al. Experimental of corrosion detection of galvanized steel strands based on magnetic memory [J]. Journal of Chang′an University (Natural Science Edition),2019,39 (1): 81-89. (in Chinese)
ZHAO Y Y,ZHOU J T,XIA R C,et al. The detection of corrosion of steel strands based on weak magnetic flux leakage effect of metal magnetic memory [J]. Journal of Shenzhen University (Science and Engineering),2019,36 (3): 260-267. (in Chinese)