Experiment on vibration characteristics of double-suction centrifugal pump under multiple working conditions
1. National Research Center of Pumps, Jiangsu University, Zhenjiang, Jiangsu 212013, China; 2. School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou, Gansu 730050, China
Abstract:To investigate the vibration characteristics of a double-suction centrifugal pump under different working conditions, the shell vibration test and the shaft vibration test of the centrifugal pump unit under different working conditions were carried out by LMS Test.Lab test system. The shell vibration, the shaft vibration and the axis trajectory of the pump were tested at 5 flow points and 5 rotating speeds. The frequency spectrum of the shell vibration and shaft vibration changed with flow rate and rotating speed was obtained by data processing. The experimental results show that the vibration intensity of shell vibration is fluctuated with the increasing of flow rate and is increased with the increasing of rotational speed. The size and variation trend of shell vibration are different at different measuring points and in different directions. The peak displacement of axial vibration is nonlinearly increased with the increasings of flow rate and rotation speed. The shell vibration spectra of different measuring points and directions are different, which indicates that there are much fluid-induced vibration. The trends of axial vibration with flow rate and rotation speed are similar in the two mutually perpendicular directions. The changes of flow rate and rotation speed have obvious influence on the axis trajectory.
LANG T,LIU Y T,CHEN K Q,et al.Review of research on hydrodynamic noise of centrifugal pump[J]. Journal of Drainage and Irrigation Machinery Engineering,2021,39(1):8-15.(in Chinese)
[2]
TAN L, ZHU B S, WANG Y C, et al. Numerical study on characteristics of unsteady flow in a centrifugal pump volute at partial load condition[J]. Engineering Computations,2015,32(6):1549-1566.
JIANG A H, ZHANG Z Y, ZHANG Y, et al. Review and outlook of studying on noise of centrifugal pumps[J]. Journal of Vibration and Shock, 2011,30(2):77-84. (in Chinese)
YANG J J,LI X J,PAN Z Y,et al. Effects of cavitating flow on induced pressure fluctuation near tongue in double-volute centrifugal pump[J].Journal of Drainage and Irrigation Machinery Engineering,2020,38(5):445-450.(in Chinese)
[5]
MENZLER F, HAUBOLD A D, HWANG N H. Dyna-mic characterization of a new accelerated heart valve tester [J]. Asaio Journal, 1997, 43(5):372-377.
YIN J N,YUAN S Q,LUO Y,et al. Analysis of vibration signal characteristics of centrifugal pump impeller under different wear degrees[J]. Journal of Drainage and Irrigation Machinery Engineering,2020,38(2):139-144.(in Chinese)
WANG X H, LI Y,LIU H L,et al. Influence of geome-trical parameters of vibration damping raft on vibration characteristics of marine centrifugal pump[J]. Journal of Drainage and Irrigation Machinery Engineering, 2019,37(11):929-935.(in Chinese)
YANG B,PAN Z Y,FALL I. Analyses of gas-liquid two-phase flow and pressure fluctuation during start-up of municipal waterlogging self-priming pump[J]. Journal of Jiangsu University (Natural Science Edition), 2020,41(5):516-522.(in Chinese)
CHEN C S, MA J, LIU R F, et al. Experimental study on centrifugal pump vibration in different operation conditions[J]. Journal of Noise and Vibration Control, 2012,12(6):199-202.(in Chinese)
LI T,LIAO G M. Energy consumption analysis of energy dissipation structure with fail-safe layers[J]. Journal of Jiangsu University (Natural Science Edition), 2021,42(3):346-353.(in Chinese)