Abstract:A special system of model test for flow pattern in a suction box of pumping station was designed, and a new method is put forward to carry out the model test for verifying a vertices band in suction box without relative model pump. Examples of model test applying the new method to verify vertices band in both “half elbow” suctionb oxa nd “bell-like” two-way suction box are illustrated respectively. Based on the two examples the advantages of the new method are summarized.
陆林广;冷豫;吴开平;祝婕. 泵站进水流道内部流态模型试验方法研究[J]. 排灌机械工程学报, 2005, 23(3): 17-19.
LU Lin-guang, LENG Yu, WU Kai-ping, ZHU Jie. Study on Method for Model Test of Flow Pattern in Suction Box of Pumping Station. Journal of Drainage and Irrigation Machinery Engin, 2005, 23(3): 17-19.