(1.School of Energy and Power Engineering,Yangzhou University,Yangzhou,Jiangsu 225127,China;2.Jiangsu Water Conservancy Project Construction Bureau,Nanjing,Jiangsu 210029,China)
Abstract:In order to directly obtain operation parameters,energy performances of large pumping stations were determined on the spot and analyzed.The discharges of water pumps were measured with five-hole probes and ADCP(acoustic doppler current profiler).Pump assembly head,input power of electrical motors and pump assembly efficiency were obtained through the data measured by measuring apparatus of the pumping station.The test precision of discharge and efficiency was analyzed.The efficiency conversion methods from model to prototype of the pump and the pump assembly were checked.The results indicate that the velocity distribution in cross section measured with five-hole probes can repeat very well,which stands for the actual axial velocity distribution in cross section.The test precision of the discharge and the efficiency could be controlled within 2.0%,which could meet the demand of field test of large pumping stations.The pump discharge and pump assembly efficiency are 11.837 8 m3/s,55.998% respectively when pump assembly head is 1.73 m,which meets the design demands of the pump assembly.The efficiency of prototype pump and pump assembly is obviously higher than that of model respectively because of size effect,and could be predicted accurately based on model efficiency by related suitable formulas.
仇宝云, 冯晓莉, 朱庆元, 何钟宁, 葛强. 大型泵站能量特性现场测试研究[J]. 排灌机械工程学报, 2011, 29(4): 322-327.
Qiu Baoyun,Feng Xiaoli,Zhu Qingyuan,He Zhongning,Ge Qiang. Investigation on field test of energy performances of large pumping station. Journal of Drainage and Irrigation Machinery Engin, 2011, 29(4): 322-327.
[1]王力勇.均速管流量计的现状与发展[J].航空计测技术,2001,21(4):21.[2]李志敏.ADCP流量测验应用研究[J].广西水利水电,2003(3):7-10.[3]Kinzli K D, Martinez M, Oad R, et al. Using an ADCP to determine canal seepage loss in an irrigation district [ J ]. Agricultural Water Management, 2010,97 ( 6 ) :801 - 810.[4]周济人,杨华,成立,等.超声波流量计测试大型低扬程泵站流量的模型试验[J].排灌机械,2009,27(1):51-54.[5]Lozano D, Mateos L. Field evaluation of ultrasonic flowmeters for measuring water discharge in irrigation ca- nals[J]. Irrigatiou and Drainage,2009,58 (2): 189 -198.[6]仇宝云,黄季艳,袁寿其 等.轴流泵出水管内部流动水力特性研究[J].农业机械学报,2005,36(12):47-50.[7]Qiu Baoyun,Cao Haihong,Jiang Wei, et al. Test investi- gation on hydraulic losses in the discharge passage of anaxial-flow pump [ J ]. Frontiers of Mechanical Engineering in China,2007,2( 1 ) :50 -56.[8]Zhang Desheng, Shi Weidong, Chen Bin,et al. Numerical simulation and flow field measurement of high-efficiency axial-flow pump [ C ] //Proceeding of the ASME 2009Fluids Engineering Division Summer Meeting and Exhibi- tion,2009 : FEDSM2009 - 78100.