Abstract:In order to optimize the type and number of pumps, operation parameters of pumping stations in multisource water injection systems simultaneously, a mathematical model was established, in which the input power of pumps is objective function, the water balance in system, flow rate and operating pressure as well as type of pumps are served as constraint conditions. Taking the features of this optimization problem in account, a dual coding was proposed to improve the existing genetic algorithm, and then was appied to solve the mathematical model. In that dual coding, a real number was adopted in the row in the coding to indicate the flow rate of a pump, an integer was put into the second row to present the number of a water injection station where the pump was installed; thus, an exact discribtion of the optimization variables was realized; obviously, the coding of solution was in variable length. An approach was porposed, where the type of pump was determined initially according to a flow rate, then the rest operating parameters of the pump were decided based on the known type. In applications of the improved genetic algorithm, the method for generating of initial solutions was given; meanwhile, a variety of crossover and mutation methods, which were adaptable to the optimization problem, were cast. As a result of this, a part of the constraint conditions were satisfied, and the number of infeasible solutions was reduced. The water injection system in an oil field with deep oil wells was optimized by using the algorithm proposed, the total input power was reduced by 2.42%, showing simultaneously optimizating pump seclection and pump operating parameters has a remarkable energy saving effect in the multisource water injection system.
杨建军, 战红, 丁玉成. 考虑配置的多源注水系统泵站运行方案优化[J]. 排灌机械工程学报, 2012, 30(4): 442-446.
YANG Jian-Jun, ZHAN Hong, DING Yu-Cheng. Optimizating pump station operation scheme and pump selection in multi source water injection systems. Journal of Drainage and Irrigation Machinery Engin, 2012, 30(4): 442-446.
[1]Ulanicki B, Kahler J, See H. Dynamic optimization approach for solving an optimal scheduling problem in water distribution systems[J]. Journal of Water Resources Planning and Management,2007,133(1): 23-32.[2]Manuel L I, Prasad T D, Paechter B. Ant colony optimization for optimal control of pumps in water distribution networks[J]. Journal of Water Resources Planning and Management,2008, 134(4):337-346.[3]Moreno M A, Planells P, Corcoles J I, et al. Development of a new methodology to obtain the characteristic pump curves that minimize the total cost at pumping stations[J]. Biosystems Engineering,2009,102(1):95-105.[4]袁一星,钟丹,高金良.基于宏观模型的给水管网优化运行研究[J].中国给水排水,2010, 26(5):55-59.Yuan Yixing, Zhong Dan, Gao Jinliang. Optimization operation of water distribution system based on macroscopic model[J]. China Water & Wastewater, 2010, 26(5):55-59. (in Chinese)[5]杨建军,战红.复杂多源注水系统变频调速优化改进遗传算法[J].沈阳工业大学学报,2010, 32(5):559-563.Yang Jianjun, Zhan Hong. Improved genetic algorithm for optimization of variable frequency speed regulation in complex multisource water injection system[J]. Journal of Shenyang University of Technology, 2010, 32(5):559-563. (in Chinese)[6]Broad D R, Maier H R, Dandy G C, et al. Optimal operation of complex water distribution systems using metamodels[J]. Journal of Water Resources Planning and Management, 2010, 136(4):433-443.[7]冯晓莉,仇宝云,杨兴丽,等.大型泵站运行优化方法及其应用[J].排灌机械工程学报,2011,29(2):127-132.Feng Xiaoli, Qiu Baoyun, Yang Xingli, et al. Optimal methods and its application of large pumping station operation[J]. Journal of Drainage and Irrigation Machinery Engineering, 2011,29(2):127-132. (in Chinese)[8]Vanzyl J E, Savic D A, Walters G A. Operational optimization of water distribution systems using a hybrid genetic algorithm[J]. Journal of Water Resources Planning and Management, 2004, 130(2):160-170.[9]Ostfeld A, Tubaltzev A. Ant colony optimization for leastcost design and operation of pumping water distribution systems[J]. Journal of Water Resources Planning and Management, 2008, 134(2):107-118.[10]姜海萍,周锦良.原水厂取水泵房水泵机组的配置改造[J].中国给水排水,2008,24(16):33-34.Jiang Haiping, Zhou Jinliang. Configuration reconstruction of pumping station unit in raw water plant[J]. China Water & Wastewater, 2008,24(16):33-34. (in Chinese)[11]程吉林,张礼华,张仁田,等. 泵站单机组变速运行优化方法研究[J].农业机械学报, 2010,41(3):72-76.Cheng Jilin, Zhang Lihua, Zhang Rentian, et al. Optimal methodology of singleunit variable speed operation in pumping station[J]. Transactions of the Chinese Society for Agricultural Machinery,2010,41(3):72-76.(in Chinese)