Abstract:This paper introduces the effects of the axial force of magnetism pump. With the type 200GYC 60 in line magnetism pump as an example, the causes for the axial force are analyzed. The formula to calculate various axial forces are listed and calculation results are given, which are the verified by test. In the end, the paper also discusses various approaches to change the axial force.
何朝辉;陈存东;王拥军. 管道式磁力泵轴向力研究[J]. 排灌机械工程学报, 2000, 18(6): 3-7.
HE Zhao hui, CHEN Cun dong, WANG Yong jun. Research on the Axial Force of the In-Line Magnetism Pump. Journal of Drainage and Irrigation Machinery Engin, 2000, 18(6): 3-7.