Abstract:In order to solve the impedance matching problem for conducted EMI filter designing of artificial mains network (AMN) impedance, noise source impedance, load impedance and EMI filter impedance, the error theoretical model and equivalent circuits of insertion loss (IL) method were established. The measurement accuracy and system error of series and parallel IL methods were analyzed to provide improved test condition and methods. Series IL method was used when the measured impedance was much larger than load impedance. Parallel IL method was utilized when the measured impedance was much smaller than load impedance. The load impedance was altered when the measured impedance approximately equaled to load impedance. Theoretical analysis and experimental results show that the proposed method can extract EMI noise impedance effectively in certain range, where it can also realize the maximum impedance adapter between noise impedance and EMI filter. The proposed method has good validity for EMI filter design and conducted EMI noise suppression.