Failure analysis and improvement for QDP-200 submersible pump based on tests and CFD |
ZHANG Jin-feng, YUAN Shou-qi, LU Wei-gang |
Technical and Research Center of Fluid Machinery Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China |
|
|
Abstract The failure reason of QDP-200 plastic submersible pump was analyzed by the performance and temperature increase tests.Computational Fluid Dynamics(CFD)simulation is also conducted for the whole flow passage.From the two aspects of tests and the inner flow law,the reasons of the pump′s poor performance are found,which are due to the simplified hydraulic design and ill-match between impellers and volute.Meanwhile,unreasonable modularization manufacture will bring about hidden troubles for the users.Some improving measures and suggestions are presented.
|
Received: 08 August 2013
|
|
|
|
[1] 关醒凡.现代泵设计手册[M].北京:宇航出版社,1995[2] 李文广.第21届IAHR水力机械及系统学术讨论会泵论文述评[J].水泵技术,2003(4):24-38[3] 赵斌娟,袁寿其,李红.双吸式叶轮内流三维数值模拟及性能预测[J].农业工程学报,2006,22(1):101-104[4] 刘厚林,袁寿其,施卫东.双流道泵叶轮内湍流的数值模拟[J].农业工程学报,2002,18(2):9-12[5] 龙志军,裴毅,杨晓珍.离心泵叶轮内部湍流流场的数值模拟[J].排灌机械,2005,23(2):8-10[6] 王福军,黎耀军,王文娥.水泵CFD应用中的若干问题与思考[J].排灌机械,2005,23(5):1-10[7] 陶文铨.数值传热学[M].西安:西安交通大学出版社,2001 |
|
|
|