Remodeling design on circulating pump of 600 MW power unit |
WU Chun-hua1, GUAN Rong-guo2 |
1.Hunan XD Changsha Pump Works Co.Ltd., Changsha, Hunan 410015, China; 2.Technical and Research Center of Fluid Machinery Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China |
|
|
Abstract A remodeling design of circulating pump of 600 MW power unit is introduced which adopts different conversion factors for the impeller and guide blade according to the same model pump.General design was used by taking two circulating pumps of 600 MW Panshan power plant of Tianjin,and two circulating pumps of 600 MW Jingtang power plant of Chengdu as examples.Design methods and design points were detailed from theoretical and experimental points of view.The results indicate that,adopting either different or the same conversion factors to design the impeller and the guide blade,the same property as the model pump is obtained if the difference between the conversion factor of the impeller and that of the guide blade was below 3% and the combined part transition between the impeller and the guide blade can be slippery
|
Received: 08 August 2013
|
|
|
|
[1] 吕秀龙,姜成启.SEZ型立式混流泵在引水泵站中的应用[J].排灌机械,2003,21(2):15-17[2] 肖庆荣,葛秀成,游玉萍.循环泵运行故障分析及排除[J].排灌机械,2004,22(1):47-48[3] 沈阳水泵研究所.叶片泵设计手册[M].北京:机械工业出版社,1983[4] 关醒凡.现代泵技术手册[M].北京:宇航出版社,1995[5] 贾国方.水泵在线智能监控技术的研究[J].排灌机械,2005,23(6):28-30 |
|
|
|