Cause of vibration of pump unit and measures to eliminate the vibration |
HUANG Yi-gang, ZHU Rong-sheng, CHEN Song, YUAN Shou-qi |
Technical and Research Center of Fluid Machinery Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China |
|
|
Abstract The cause for the vibration of the pump unit was discussed.Some measures to reduce the vibration were proposed concerning design installation,run and maintenance.The results indicated that the vibration of the pump unit could be alleviated through retaining some consistency between the dimension and precision of mechanical part of the pump unit,avoiding overloading,and ensuring the pump unit worked under the design requirements.pump;vibration;hydraulic design;mechanics design;motor
|
Received: 08 August 2013
|
|
|
|
[1] 顾丽娜,宋伟刚,郝杰.直流电动机振动分析与减振处理[J].黑龙江造纸,2006(1):51-52[2] 曾培,肖开华,袁铁军.磁力泵滑动轴承磨损监测系统的设计[J].排灌机械,2006,24(5):36-39[3] 龙新平,王磊.液体射流泵空化噪声与振动试验[J].排灌机械,2007,25(4):1-5[4] 钱利华.电厂循环供水泵站立式异步电动机振动分析[J].排灌机械,2006,24(2):31-32[5] 淮慧海,朱晓辉.水泵振动原因及对策[J].机械工程与自动化,2004(1):59-61[6] 仇宝云,魏强林,林海红.大型水泵导轴承应用研究[J].流体机械,2006,34(11):12-15[7] 车焕君.水泵振动原因及消除措施[J].中国设备工程,2003(4):27-28[8] 张义民.机械振动[M].上海:上海交通大学出版社,1985:8-29[9] 袁寿其.低比速离心泵理论与设计[M].北京:机械工业出版社,2006:45-112[10] 李大亮,张晓芳,陈松山.泵站出口流道的优化试验[J].排灌机械,2007,25(4):30-33[11] 马希金,肖兴均.轴流泵油气混输泵吸入室及压缩流场分析[J].排灌机械,2007,25(1):14-16 |
|
|
|