Data Erro Reason Analysis of one Pump Tested in Different Test Bed |
LIU Qiang, WANG Yang, WANG Zhuen |
Research Center of Fluid Machinery Engineering and Technology of Jiangsu University, Zhenjiang, Jiangsu, 212013, China |
|
|
Abstract In order to improve the precision of the product test, the test data of FHE40-160-40 typeelectric pump is taken for example, which tested in two test beds that match with the precision of GB/T 3216 Cgrade respectively, and the reason of result deviation is analyzed. The main influent factor of the test result ispointed out to be the asymmetric of three-phase power; in addition, the precision of the test instrument, themode of line connection etc. are also the influent factors.
|
Received: 08 August 2013
|
|
|
|
[1] .GB/T3216-1989.离心泵、混流泵、轴流泵和旋涡泵试验方法[S].[2] .GB/T12785-2002.潜水电泵试验方法[S].[3] .GB/T1032-1985.三相异步电动机试验方法[S].[4] 关醒凡.现代泵技术手册[M].北京:宇航出版社,1995[5] 汤跃,等.泵试验理论与方法[M].北京:兵器工业出版社,1995[6] 胡虔生,等.电机学[M].北京:中国电力出版社,2001[7] 叶文荪,等.电工技术[M].北京:机械工业出版社,1998 |
|
|
|