Improvements of Flow Pattern of Double Inlet Passage |
CHEN Yu ling1, XU Hui1, WU Xin ming2 |
1. College of Water Conservancy and Hydropower Engineering, Hohai Univ., Nanjing, Jiangsu 210098, China; 2. Management Institute of Sluice and Pumping Station in Siyang, Siyang, Jiangsu 223700, China |
|
|
Abstract Based on the model experiments for the 1st and 2nd double suction dock pumping station in Shanghai Waigaoqiao Ship Manufacture Base, the hydraulic characteristics of inlet system of double suction pumping station are investigated here. Also, the causes and damages of the reverse-flow and vortex in the intake chambers are analyzed theoretically, and the measurements to improve the inlet flow patterns are presented.
|
Received: 07 August 2013
|
|
|
|
[1] 武汉水利电力学院,华东水利学院.水力学[M].北京:人民教育出版社,1981:317-319[2] 仲付维.泵站工程[M].南京:河海大学出版社,1994:43-48[3] 田家山.给、排水泵站进水液压态紊乱的危害及对策[J].河海大学学报(自然科学版),1988,16(2):16-18[4] 田家山.泵站侧向进水流态的评价与整治[J].河海大学学报(自然科学版),1989,17(Z1):8-14 |
|
|
|