Abstract:A new high-accuracy diverter for primary water flow standard facility has been developed by hydraulic machinery laboratory at IWHR, China. As the core of water calibration facility, diverter determines the test accuracy. Diverter uncertainty test was performed according to China verification code of JJG 164—2000, getting the result that combined standard uncertainty of diverter UDrel is less than 0.015%(k=2). In order to analyze the dynamic principal characteristic, numerical simulation method was adopted, which employs VOF multiphase model and k-ε turbulence model to obtain the water volume fraction inside diverter and to calculate the collecting rate for different positions. By high-speed camera, the operation procedure of the diverter has been obtained, and the dynamic curve and the ti-ming trigger position have been achieved. The results have been applied to calibrate large flow in situ and large diameter flowmeter.
[1]何成连,蒋玉华,张智彬,等. 南水北调工程水泵模型同台测试及试验台简介[J]. 水利水电工程设计,2006,25(2): 29-32. He Chenglian, Jiang Yuhua, Zhang Zhibin, et al. The brief introduction for pump model test and experiment of south-to-north water diversion project[J]. Design of Water Resources & Hydroelectric Engineering,2006,25(2): 29-32.(in Chinese)[2]IEC 60193-1999,Hydraulic Turbines, Storage Pumps and Pump-Turbines-Model Acceptance Tests[S].[3]黄源芳,熊腾晖,田子勤. 三峡水轮机模型目击验收试验剖析[J]. 水力发电,2001(5):43-47. Huang Yuanfang, Xiong Tenghui, Tian Ziqin. Analysis on visual acceptance tests of the turbine model for the Three Gorges Project[J]. Water Power,2011(5):43-47.(in Chinese)[4]陈忠宾,高从闯,刘徽. 溧阳抽水蓄能电站水泵水轮机模型同台对比复核试验简介[C]//抽水蓄能电站工程建设文集.北京:中国电力出版社,2010:255-258.[5]陆力,高忠信,潘罗平,等. 50年来水力机电研究领域发展与回顾[J]. 中国水利水电科学研究院学报,2008,6(4):299-307. Lu Li,Gao Zhongxin, Pan Luoping, et al. Review and prospect on hydraulic machinery research in the past 50 years [J]. Journal of China Institute of Water Resources and Hydropower Research,2008,6(4):299-307.(in Chinese)[6]王秀瑛. 流量计量在自来水行业中的应用及发展[J]. 山西建筑,2002,28(5):89-90. Wang Xiuying. The application and development of flow measuring in water supply industry [J]. Shanxi Architecture,2002,28(5):89-90.(in Chinese)[7]吴新生,廖小永,王黎,等. 外贴式超声波流量计的测量与在线校准[J]. 人民长江,2013,44(11):72-75. Wu Xinsheng, Liao Xiaoyong, Wang Li, et al. Research on measurement and on-line calibration of outside-attached ultrasonic flow meter [J]. Yangtze River,2013,44(11):72-75.(in Chinese)[8]孟涛,王池,陈海滨,等. 用模型实验方法研究三峡电站流量计准确度[J]. 计量学报,2010,31(6):509-512. Meng Tao, Wang Chi, Chen Haibin, et al. Study on the accuracy of flowmeter at Three Gorges power station by model experiment method [J]. Acta Metrology Sinica,2010,31(6):509-512.(in Chinese)[9]孟涛,王池,陈晓铭. 流量装置中换向器检定方法的研究[J]. 计量学报,2008,29(5):420-422. Meng Tao, Wang Chi, Chen Xiaoming. Research on verification method of diverters in liquid flow facilities [J]. Acta Metrology Sinica,2008,29(5):420-422.(in Chinese)[10]Yeh T T, Yende N P, Johnson A N, et al. Error free liquid flow diverters for calibration facilities[C]//Proceedings of the 2002 ASME Joint U.S., 2002:141-148.[11]Pöschel W, Engel R, Dopheide D, et al. A unique fluid diverter design for water flow calibration facilities[C]//Proceedings of the 10th International Conference on Flow Measurement, 2000.[12]Marfenko I, Yeh T T, Wright J. Diverter uncertainty less than 0.01% for water flow calibrations[C]//Proceedings of the 6th International Symposium for Fluid Flow, 2006.[13]Doihara R, Shimada T, Terao Y, et al. Development of weighing tank system employing rotating double wing diverter[J]. Flow Measurement and Instrumentation, 2006, 17(3): 141-152.[14]JJG 164—2000,液体流量标准装置检定规程[S].[15]Hirt C W, Nichols B D. Volume of fluid method for the dynamics of free boundaries[J]. Journal of Computational Physics, 1981, 39(1): 201-225.[16]吴玉林,唐学林,刘树红,等. 水力机械空化和固液两相流体动力学[M]. 北京:中国水利水电出版社,2007:92-98.[17]Yang W, Liu S H, Lin H. Viscous liquid sloshing damping in cylindrical container using a volume of fluid method[J]. Science in China Series E: Technological Sciences, 2009, 52(6): 1484-1492.