Abstract:Because the surfacewater in upper region of the Yangtze River contains large amounts of silt and algae, high content of microorganisms and suspended solids, it can not be directly used as circulating cooling water in the river water source heat pump unit. In order to solve the problem, the water temperature and quality of Yangtze River in Chongqing area were analyzed, the principle of application of water to prevent clogging of the filter device was introduced, and the performance of clean up and anti-clogging of device was tested through experiment. The experimental results show that the river sediment can be reduced to 100 g/m3 after filtration,with an average removal rate of 68.5%,and suspended solids and algae levels also decreased to 50-100 NTU basically, with its average removal rate is 73.1%, which can meet the requirements of water quality into heat pump unit directly. The load impedance of pipe lines matches the characteristic impedance, and the water hammer pressure amplitude is small. It can resolve the key technical problems of clean up, anticlogging and anti water hammer when the surface water runs into the heat pump in the upper Yangtze River region. The entire separation system is simple, easy installation, reliable operation, low operation cost, and can be automatic cleaning, filtering and sewage residue automatic draining using the water flow and gravity, so it has great application prospects in the surface water source heat pump system in the Yangtze River region.
童明伟, 秦增虎. 进入热泵机组的江水水质与过滤特性试验[J]. 排灌机械工程学报, 2011, 29(2): 104-108.
Tong Mingwei, Qin Zenghu. Experiment on filtration characteristics and water quality of Yangtze River water into heat pump unit. Journal of Drainage and Irrigation Machinery Engin, 2011, 29(2): 104-108.
1]Bǔyǔkalaca O,Ekinei F,Yilmaz T.Experimental investigation of Seyhan River and dam lake as heat sourcesink for a heat pump[J]. Energy ,2003,28(2):268-271.[2]陈 超,倪 真,李小宁,等.住宅建筑中闭式水源热泵空调系统的应用研究[J].暖通空调,2004,34(6):72-76.Chen Chao,Ni Zhen,Li Xiaoning,et al.Application of closed loop water source heat pump air conditioning system to residential buildings[J]. Journal of HV & AC ,2004,34(6):72-76. (in Chinese)[3]王子云,付祥钊,仝庆贵. 利用长江水作热泵冷热源的探讨[J]. 暖通空调,2008,38(4):31-34.Wang Ziyun,Fu Xiangzhao,Tong Qinggui. Discuss on using Yangtze River water as heat and cold sources of water source heat pumps[J]. Journal of HV & AC ,2008,38(4):31-34. (in Chinese)[4]江 琴,季赐明. 直流冷却在广州地铁集中供冷系统中的应用[J]. 给水排水,2005,31(7):71-72.Jiang Qin,Ji Ciming. Application of DC cooling in Guangzhou metro central cooling system[J]. Water and Wastewater Engineering ,2005,31(7):71-72. (in Chinese)[5]孙德兴,吴荣华. 城市污水冷热源的应用方法和装置:中国,CN03132553.X[P]. 2004-02-11.[6]孙新忠. 离心筛网一体式微灌式过滤器的试验研究[J]. 排灌机械,2006,24(3):20-23.Sun Xinzhong. Experiments on integral centrifugal screen panel and microirrigation filter[J]. Drainage and Irrigation Machinery ,2006,24(3): 20-23. (inChinese)[7]童明伟,项 勇,秦增虎. 一种水流旋转除渣防堵装置:中国,CN200920128816.7[P]. 2010-06-16.[8]童明伟,秦增虎. 浊水过滤自动排渣器:中国,CN200810233018.0[P]. 2009-04-29.[9]翟世奎,张怀静,范德江,等. 长江口及其邻近海域悬浮物浓度和浊度的对应关系[J].环境科学学报,2005,25(5):693-699.Zhai Shikui,Zhang Huaijing,Fan Dejiang,et al. Corresponding relationship between suspended matter concentration and turbidity on Changjiang estuary and adjacent sea area[J]. Acta Scientiae Circumstantiae ,2005,25(5):693-699. (in Chinese)[10]姚青云,李志敏. 事故停泵水锤对压力管道的影响[J]. 排灌机械,2006,24(6):45-47.Yao Qingyun,Li Zhimin. Effect of water hammer to pressure pipes for pumping accidents[J]. Drainage and Irrigation Machinery ,2006,24(6):45-47. (in Chinese)[11]Singh R K, Sinha S K, Rama R A. Study of incident water hammer in an engineering loop under twophase flow experiment[J]. Nuclear Engineering and Design,2010,240(8):1967-1974.