Abstract: Based on the working principle of complete fluidic sprinkler′s fluidic element and its inner flow state,factors that affect the frequency of wall attachment offset jet are analyzed.A calculating formula of frequency is established by the differential pressures on both sides of fluidic element.The wall fluctuating pressures of fluidic element are measured and converted to the experimental data of wall attachment frequency.The calculating results of frequency agree well with the experimental data.Both the experimental data and the calculating results show that the frequency decreases with the signal pipe length and increases with the fluidic element′s cavity volume.The frequency increases with the sprinkler′s working pressure and the flow rate of signal water.As far as the type of PXH30 sprinkler is concerned,the wall attachment frequencies are linear with the flow rate of signal water.The Reynolds number has little influence on the Strouhal number,and the Strouhal number reduces with the Euler number increasing.The study provides the guide for the design of fluidic element and the adjustment of sprinkler′s working state.
[1]袁寿其,朱兴业,李红,等.全射流喷头重要结构参数对水力性能的影响[J].农业工程学报,2006,22(10):113-116.Yuan Shouqi,Zhu Xingye,Li Hong,et al.Effects of complete fluidic sprinkler on hydraulic characteristics based on some important geometrical parameters[J].Transactions of the CSAE,2006,22(10):113-116.(in Chinese)[2]朱兴业,袁寿其,李红.全射流喷头与摇臂式喷头的对比实验[J].农业机械学报,2008,39(2):70-72,184.Zhu Xingye,Yuan Shouqi,Li Hong.Compared experiments between complete fluidic sprinkler and impact sprinkler[J].Transactions of the Chinese Society for Agricultural Machinery,2008,39(2):70-72,184.(in Chinese)[3]李世英.喷灌喷头理论与设计[M].北京:兵器工业出版社,1995.[4]廖振方,邓晓刚,李军.涡腔式自激振荡射流喷洒装置[J].重庆大学学报,2002,25(12):1-3.Liao Zhenfang,Deng Xiaogang,Li Jun.Self-exited oscillation vortex chamber watering device[J].Journal of Chongqing University,2002,25(12):1-3.(in Chinese)[5]周瑞章.旁路振荡式气体流量计[J].液压气动与密封,1994(4):15-17.Zhou Ruizhang.Bypass vibration type gas flowmeter[J].Hydraumatic Pneumatic and Sealing,1994(4):15-17.(in Chinese)[6]傅新,王驰宇,谢海波,等.射流流量计的仿真与试验研究[J].机械工程学报,2006,42(7):24-28.Fu Xin,Wang Chiyu,Xie Haibo,et al.Numerical simulation and experimental study on fluidec flowmeter[J].Chinese Journal of Mechanical Engineering,2006,42(7):24-28.(in Chinese)[7]Lua A C,Zheng Z.Numerical simulations and experimental studies on a target fluidic flowmeter[J].Flow Measurement and Instrumentation,2003,14(2):43-49.[8]向清江,朱兴业.全射流喷头内部附壁点距离的计算[J].排灌机械,2008,26(3):55-58.Xiang Qingjiang,Zhu Xingye.Calculation on distance of wall-attachment point in complete fluidic sprinkler[J].Drainage and Irrigation Machinery,2008,26(3):55-58.(in Chinese)