Abstract:Fertigation technology for center pivot irrigation systems has increasingly become a research focus in precision agriculture inside and outside China. Fertigation equipment with high working pre-ssure and low but stable flow rate is the key factor to guarantee high fertigation uniformity. In order to meet the requirement of center pivot irrigation systems a double-cylinder plunger pump including liquid ends, drive ends, pistons, seals, AC motor and so on was designed by taking crop fertilization characteristics into account. The design flow rate per cylinder is 150 L/h and the maximum working pressure is 1.0 MPa. Meanwhile 100 h durability test, stroke regulation test(20%-100% stroke)and frequency conversion test(30-50 Hz)on a prototype of the pump were conducted. It was showed that the discharge of the pump decreases with increasing discharge pressure and all the variation coefficients of discharge within 100 h are smaller than 5% under various discharge pressures. The measured discharge is almost the same as the theoretical one, and the maximum error between them is just 7.5% at a 60% stroke. Additionally, the pump discharge rises linearly with AC motor frequency. Clearly, the pump discharge can be adjusted by changing the plunger stroke and altering the AC motor frequency to expand the range of pump discharge. The developed plunger pump is applicable for a fertigation system, such as the center pivot irrigation system to realize precision fertilization.
严海军, 王志鹏, 马开. 圆形喷灌机注肥泵的设计与试验研究[J]. 排灌机械工程学报, 2014, 32(5): 456-460.
Yan Haijun, Wang Zhipeng, Ma Kai. Design and experiment on fertigation plunger pump in center pivot irrigation system. Journal of Drainage and Irrigation Machinery Engin, 2014, 32(5): 456-460.
[1]Threadgill E D. Chemigation via sprinkler irrigation: Current status and future development[J]. Applied Engineering in Agriculture, 1985,1(1):16-23.[2]Tanaskovik V, Cukaliev O, Romic D, et al. The influence of drip fertigation on water use efficiency in tomato crop production[J]. Agriculturae Conspectus Scientificus, 2011,76(1):57-63.[3]USDA. 1998 farm and ranch irrigation survey: Census of agriculture[R]. National Agricultural Statistics Ser-vice.Washington,DC:US Department of Agriculture, 1998.[4]Eisenhauer D E, Bockstadter T L. Injection pump flow considerations for center pivots with corner watering systems[J]. Transactions of the American Society of Agricultural Engineers, 1990,33(1):162-166.[5]Threadgill E D. Introduction to chemigation: History, development, and current status[C]//Proceedings of the Chemigation Safety Conference. Lincoln, USA: University of Nebraska Cooperative Extension, 1985.[6]Bracy R P,Parish R L, Rosendale R M. Fertigation uni-formity affected by injector type[J]. Hort Technology, 2003,13(1):103-105.[7]张承林,郭彦彪. 灌溉施肥技术[M]. 北京:化学工业出版社,2006.[8]King B A, Wall R W, Taberna J P Jr. Spatially distri-buted control network for flow proportional chemical injection with center pivot sprinkler irrigation[J]. Applied Engineering in Agriculture, 2009,25(5):677-683.[9]严海军,朱勇,白更,等. 对内蒙古推广使用大型喷灌机的思考[J]. 节水灌溉,2009(1):18-21. Yan Haijun, Zhu Yong, Bai Geng, et al. Discussion on application of large-sized sprinkler irrigation machines in Inner Mongolia Autonomous Region[J]. Water Saving Irrigation, 2009(1):18-21.(in Chinese)[10]张承林,邓兰生.水肥一体化技术[M]. 北京:中国农业出版社,2012.[11]丛庄远,董国华,查森. 活塞泵及其它类型泵[M]. 北京:中国工业出版社,1962.[12]往复泵设计编写组. 往复泵设计[M]. 北京:机械工业出版社,1987.[13]朱俊华,战长松.往复泵[M]. 北京:机械工业出版社, 1992.[14]黄启龙,李进贤,郑亚,等. 活塞往复泵内流场非稳态数值模拟[J]. 重庆理工大学学报:自然科学,2011,25(3):6-10. Huang Qilong, Li Jinxian, Zheng Ya, et al. Numerical simulation of unsteady inner flow field in reciprocating piston pump[J]. Journal of Chongqing University of Technology: Natural Science, 2011,25(3):6-10.(in Chinese)