Treatment of high mass concentration coking wastewater using enhancement catalytic iron carbon internal-electrolysis |
State Key Laboratory of Pollution Control and Resource Reuse,Tongji University,Shanghai 200092,China) |
|
|
Abstract The treatment of coking wastewater is very difficult because of its high mass concentration pollutant,complicated components and poor biodegradability.To solve the problem,catalytic iron carbon internal-electrolysis process was adopted in the pretreatment of high concentration coking wastewater.The effects of initial pH,sewage residence time,volume ratio of Fe/C and some other key factors on the treatmentwere explored.By orthogonal test,the optimized parameters of catalytic iron carbon internal-electrolysispretreatment of coking wastewater are determined as: influent ρ(CODin)=3 200~3 500 mg/L,pH=3,V(Fe)/V(C)=1∶1,hydraulic retention time=90 min.Under the above conditions,the removalrate of COD,phenol,sulfide,degree and NH3-N are 66%,75%,73%,80% and 34% relyspective,and its biodegradability(BOD5/COD) is also improved from 0.25 to 0.52.In addition,the reactivity is greatly increased.
|
|
|
|
|
|
|
|