Power harmonic parameter estimation based on three spectral line interpolation of self-multiplication-convolution Rife-Vincent window |
College of Information Science and Engineering, Jishou University, Jishou, Hunan 416000, China
|
|
|
Abstract When the classical fast Fourier transform method is used to estimate the power harmonic parameters, the fence effect and the spectrum leakage due to non integer period truncation and asynchronous sampling can cause estimation error. To improve the accuracy of harmonic parameter estimation, combined with the advantages of self-multiplication and self-convolution window, a self-multiplication-convolution window was designed based on Rife-Vincent window. With good sidelobe characteristics, the proposed window could effectively suppress spectrum leakage. The estimation formulas of harmonic amplitude, frequency and phase were obtained based on three spectral line interpolation and least square fitting. The simulation experiments were performed under the conditions of complex harmonics, interharmonics and fundamental frequency fluctuations with weak amplitudes. The results show that the proposed algorithm has higher detection accuracy than the classical windowed algorithm.
|
Received: 10 November 2021
|
|
|
|
[1] |
GORLA N Y, KOLLURI S, CHAI M L, et al. A comprehensive harmonic analysis and control strategy for improved input power quality in a cascaded modular solid state transformer[J]. IEEE Transactions on Power Electronics, 2018, 34(7): 6219-6232.
|
[2] |
杨帆,李晓明,郑秀玉,等.电力系统分数次谐波的产生机理、危害与特征[J].高电压技术, 2007(12): 153-156.
|
|
YANG F, LI X M, ZHENG X Y, et al. Representative characteristics, emergence mechanism and their harms for fraction harmonics[J]. High Voltage Engineering, 2007(12): 153-156.(in Chinese)
|
[3] |
李振华,胡廷和,杜亚伟,等.基于窗函数和谱线插值理论的谐波检测方法[J].电力系统保护与控制, 2019, 47(22): 78-88.
|
|
LI Z H, HU T H, DU Y W, et al.Harmonic detection method based on the theory of windows and spectrum line interpolation[J].Power System Protection and Control, 2019, 47(22): 78-88. (in Chinese)
|
[4] |
SHUAI Z K, WEN H, CHAO S, et al. Characteristics and restraining method of fast transient inrush fault currents in synchronverters[J]. IEEE Transactions on Industrial Electronics, 2017, 64(9): 7487-7497. (in Chinese)
|
[5] |
WANG X F, BLAABJERG F. Harmonic stability in power electronic based power systems: concept, modeling, and analysis[J]. IEEE Transactions on Smart Grid, 2018, 10(3): 2858-2870.(in Chinese)
|
[6] |
王保帅,肖霞.一种用于谐波分析的高精度多谱线插值算法[J].电工技术学报, 2018, 33(3): 553-562.
|
|
WANG B S, XIAO X. A high accuracy multispectrumline interpolation algorithm for harmonic analysis[J].Transactions of China Electrotechnical Society, 2018, 33(3): 553-562. (in Chinese)
|
[7] |
KALAIR A, ABAS N, KALAIR A R, et al. Review of harmonic analysis, modeling and mitigation techniques[J]. Renewable and Sustainable Energy Reviews, 2017, 78(10): 1152-1187.
|
[8] |
徐艳春,刘宇龙,李振华,等.基于六项余弦窗四谱线插值FFT的高精度谐波检测算法[J].电力系统保护与控制,2016,44(22):56-63.
|
|
XU Y C, LIU Y L, LI Z H, et al. An accurate approach for harmonic detection based on 6term cosine window and quadruplespectrumline interpolation FFT[J]. Power System Protection and Control, 2016, 44(22): 56-63. (in Chinese)
|
[9] |
ZHUANG S Y, ZHAO W, WANG Q, et al. Four harmonic analysis and energy metering algorithms based on a new cosine window function[J]. The Journal of Engineering, 2017, 2017(14): 2678-2684.
|
[10] |
李一然,田立军,吴勇,等.基于双窗全相位FFT双谱线插值的谐波和间谐波分析算法[J].电力系统及其自动化学报, 2021, 33(4): 55-61.
|
|
LI Y R, TIAN L J, WU Y, et al. Harmonics and interharmonics analysis algorithm based on doublespectralline interpolation of doublewindow allphase FFT[J].Proceedings of the CSUEPSA, 2021, 33(4): 55-61. (in Chinese)
|
[11] |
JIN T, CHEN Y Y, FLESCH RODOLFO CC. A novel power harmonic analysis method based on NuttallKaiser combination window double spectrum interpolated FFT algorithm[J]. Journal of Electrical Engineering, 2018, 68(6): 435-443.
|
[12] |
SU T X, YANG M F, JIN T, et al. Power harmonic and interharmonic detection method in renewable power based on Nuttall doublewindow allphase FFT algorithm[J]. Iet Renewable Power Generation, 2018, 12(8): 953-961.
|
[13] |
牛胜锁,梁志瑞,张建华,等.基于三谱线插值FFT的电力谐波分析算法[J].中国电机工程学报, 2012, 32(16): 130-136.
|
|
NIU S S, LIANG Z R, ZHANG J H, et al. An algorithm for electrical harmonic analysis based on triple spectrum line interpolation FFT[J]. Proceedings of the CSEE, 2012, 32(16): 130-136.(in Chinese)
|
[14] |
陈至豪,王立德,王冲,等.基于组合余弦优化窗四谱线插值FFT的电力谐波分析方法[J].电网技术, 2020, 44(3):1105-1113.
|
|
CHEN Z H, WANG L D, WANG C, et al. An approach for electrical harmonic analysis based on optimized composite cosine window fourspectrumline interpolation FFT[J].Power System Technology, 2020, 44(3):1105-1113.(in Chinese)
|
[15] |
WEN H, TENG Z S, GUO S Y, et al. Hanning selfconvolution windows and its application to harmonic analysis[J]. Transactions of China Electrotechnical Society, 2009, 24(2):164-169.
|
[16] |
WEN H, ZHANG J H, MENG Z, et al. Harmonic estimation using symmetrical interpolation FFT based on triangular selfconvolution window[J]. IEEE Transactions on Industrial Informatics, 2015, 11(1):16-26.
|
[17] |
YAO W X, TENG Z S, TANG Q, et al. Measurement of power system harmonic based on adaptive Kaiser self convolution window[J]. Iet Generation Transmission & Distribution, 2016, 10(2):390-398.
|
[18] |
TAN T Y, CHEN W J, LIU K P, et al. Harmonic analysis based on time domain mutualmultiplication window[J]. Journal of Modern Power Systems and Clean Energy, 2016, 4(1):47-53.
|
[19] |
WANG X M, LEI K J, YANG X, et al. Harmonic analysis based on blackmanharris selfmultiplication window[C]∥2020 5th Asia Conference on Power and Electrical Engineering, 2020:2165-2169.
|
[20] |
曾博,滕召胜,温和,等.莱夫-文森特窗插值FFT谐波分析方法[J].中国电机工程学报, 2009, 29(10): 115-120.
|
|
ZENG B, TENG Z S, WEN H, et al. An approach for harmonic analysis based on RifeVincent window interpolation FFT[J].Proceedings of the CSEE, 2009, 29(10): 115-120.(in Chinese)
|
[21] |
刘涛,庄双勇,陈晓伟,等.基于Hanning自乘-卷积窗FFT三峰插值修正的电能计量新算法[J].电力系统保护与控制, 2017, 45(22): 9-15.
|
|
LIU T, ZHUANG S Y, CHEN X W, et al. A new algorithm for electric energy measurement based on Hanning selfmultiplicationconvolution window triplespectrumline interpolation FFT[J]. Power System Protection and Control, 2017, 45(22): 9-15.(in Chinese)
|
|
|
|