Calculation and analysis of auxiliary equipment dissipation energyin 3rd Datao pumping station |
Lu Yongquan1, Zhu Qingyuan1, Qiu Baoyun2, Yang Xingli2, Feng Xiaoli2, Dong Bo2 |
(1.Department of Water Resources of Jiangsu Province, Nanjing, Jiangsu 210029, China; 2.School of Energy and Power Engineering, Yangzhou University, Yangzhou, Jiangsu 225127, China) |
|
|
Abstract In order to know auxiliary equipment dissipate energy of a large pumping station, the 3rd Datao pumping station of Tongyu River north extended water supply project in Jiangsu province was taken as an example, the auxiliary equipment in the 3rd Datao pumping station was introduced, the dissipation energy of the auxiliary equipment was calculated systematically by analyzing its operational aspect. The dissipation energy characteristics of the auxiliary equipment were analyzed. The results show that the dissipation energy of auxiliary equipment is about 3.13% of the total dissipation energy of the pumping station, and the dissipation energy of illumination, trash removal and electric machine ventilation is comparatively large and shares about 1/3 of total auxiliary equipment dissipation energy respectively. The results would provide references for the design and energysa ving of large pump station auxiliary equipment.
|
Received: 11 April 2010
Published: 30 July 2010
|
|
|
|
[1]张雷.浅谈泵站辅助设备与自动化[J].黑龙江科技信息,2009(15):24.Zhang Lei.Discussion on auxiliary equipment and automation of pump station[J].Heilongjiang Science and Technology Information,2009(15):24.(in Chinese)[2]严登丰,叶健,陈茂满,等.泵及泵装置效率表达与换算[J].排灌机械,2007,25(1):1-8.Yan Dengfeng,Ye Jian,Chen Maoman,et al.Pump hydraulic stability appraisal by means of energy performances[J].Drainage and Irrigation Machinery,2007,25(1):1-8.(in Chinese)[3]潘咸昂.泵站辅助设备及自动化[M].北京:水利电力出版社,1989.[4]高朝辉,仇宝云,问泽杭.泵站拦污栅及其清污研究进展[J].排灌机械,2006,24(2):10-15.Gao Zhaohui,Qiu Baoyun,Wen Zehang.Research progress on trash rack and feculence-clearing for pump station[J].Drainage and Irrigation Machinery,2006,24(2):10-15.(in Chinese)[5]Xiang Fu,Kavvas L M,Chen Zhiqiang,et al.Experimental study of debris capture efficiency of trash racks[J].Journal of Hydro-Environment Research,2009,3(3):138-147.[6]Olivares J C,Canedob J,Moreno P,et al.Experimental study to reduce the distribution-transformers stray losses using electromagnetic shields[J].Electric Power Systems Research,2002,63(1):1-7.[7]Arri E,Locci N.Uncertainty analysis in a novel method for transformer power losses measurement[J].Measurement:Journal of the International Measurement Confederation,1994,12(4):315-320.[8]Wu Huagen,Li Jianfeng,Xing Ziwen.Theoretical and experimental research on the working process of screw refrigeration compressor under superfeed condition[J].International Journal of Refrigeration,2007,30(8):1329-1335. |
|
|
|