Design and application of fine water mist regulation system in large space of local environment |
Wang Junfeng, Tu Xincheng, Huang Jiwei, Huang Qiaomei |
(School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China) |
|
|
Abstract The design method of spray system for cooling, humidity adjusting and regulation was proposed. A mathematical model of fine water mist cooling for regulations in large space of local environment which response to the process of water mist diffusion and evaporation was established. Take the case of spray cooling system for special steel arena of the Shanghai Exposition, the result of calculation on the water consumption of system terminal and the humidity evolution revealed that in the process of spray cooling in semi-outdoor environment, the concentration of water vapor increased. The decrease in ambient temperature and saturated moisture could result in the increase of humidity in local environment. It is necessary to control the humidity evolution by using ventilation. The comparison of different ventilation rate indicated that the higher ventilation could accelerate the stabilization of humidity evolution. The ambient humidity could be kept less than 88% by setting the working frequency for spray cooling system terminal. The model was widely used and ignored some non-critical factors, such as moisture and heat gain from human body. The design, optimization and analysis of system were conducted in the engineering of Olympic Games and shedding light on the design of spray cooling system that would be applied in Shanghai Exposition and semi-outdoor environment.
|
Received: 06 November 2009
Published: 30 May 2010
|
|
|
|
[1]Kollar L E, Farzaneh M. Modeling the evolution of droplet size distribution in two-phase flows[J]. International Journal of Multiphase Flow, 2007, 33(11): 1255-1270.[2]高建民, 任宁, 顾峰, 等. 低频超声雾化喷头优化设计及试验[J]. 江苏大学学报:自然科学版, 2009, 30(1): 1-4.Gao Jianmin, Ren Ning, Gu Feng, et al. Optimum design and experiment on low-frequency ultrasonic atomizing nozzles[J]. Journal of Jiangsu University: Natural Science Edition, 2009, 30(1): 1-4.(in Chinese)[3]Sureshkumar R, Kale S R, Dhar P L. Heat and mass transfer processes between a water spray and ambient air—Ⅰ:Experimental data[J]. Applied Thermal Engineering, 2008, 28(5/6): 349-360.[4]Jia W, Qiu H H. Experimental investigation of droplet dynamics and heat transfer in spray cooling[J]. Experimental Thermal and Fluid Science, 2003, 27(7): 829-838.[5]Chen R H, Chow L C, Navedo J E. Effects of spray characteristics on critical heat flux in subcooled water spray cooling[J]. International Journal of Heat and Mass Transfer, 2002, 45(19):4033-4043.[6]岑旗钢, 王贞涛, 闻建龙. 切削加工喷雾冷却雾化特性的PDA试验[J]. 排灌机械, 2007, 25(3): 53-56.Cen Qigang, Wang Zhentao, Wen Jianlong. Experimental study on spray characteristics for metal cutting by PDA[J]. Drainage and Irrigation Machinery, 2007, 25(3): 53-56.(in Chinese)[7]Kachhwaha S S, Dhar P L, Kale S R. Experimental studies and numerical simulation of evaporative cooling of air with a water spray—Ⅰ:Horizontal parallel flow[J]. International Journal of Heat and Mass Transfer, 1998, 41(2): 447-464.[8]Kachhwaha S S, Dhar P L, Kale S R. Experimental studies and numerical simulation of evaporative cooling of air with a water spray—Ⅱ:Horizontal counter flow[J]. International Journal of Heat and Mass Transfer, 1998, 41(2): 465-474.[9]Sureshkumar R, Kale S R, Dhar P L. Heat and mass transfer processes between a water spray and ambient air—Ⅱ:Simulations[J]. Applied Thermal Engineering, 2008,28(5/6): 361-371.[10]杨洋, 黄晨, 王丽慧, 等. 世博轴喷雾降温前期调研及试验结果分析[J]. 制冷技术, 2008, 28(1): 6-10.Yang Yang, Huang Chen, Wang Lihui, et al. Analysis of research and test results of EXPO axis spray cooling[J]. Refrigeration Technology, 2008, 28(1): 6-10.(in Chinese)[11]Yamada H, Yoon G, Okumiya M, et al. Study of cooling system with water mist sprayers: Fundamental examination of particle size distribution and cooling effects[J]. International Journal of Building Simulation, 2008, 1(3): 214-222.[12]王军锋, 屠欣丞, 黄俏梅, 等. 半室外环境两相流低压雾化降温数值分析[J]. 排灌机械, 2009, 27(4): 255-260.Wang Junfeng, Tu Xincheng, Huang Qiaomei, et al. Numerical analysis of cooling process in two-phase flow by low pressure atomization in semi-outdoor environment[J].Drainage and Irrigation Machinery, 2009, 27(4): 255-260.(in Chinese)[13]沈维道, 蒋智敏, 童钧耕. 工程热力学[M]. 3版. 北京: 高等教育出版社, 2000: 356-357.[14]朱颖心. 建筑环境学[M]. 北京: 中国建筑工业出版社, 2005: 26-27.[15]陆亚俊, 马最良, 邹平华. 暖通空调[M]. 北京: 中国建筑工业出版社, 2007: 200-201. |
|
|
|