Technology evaluation of single-stage and single-suction rinsing centrifugal pump |
MU Jie-gang1, ZHANG Xin2, HUANG Zhong-hong3 |
1.Industrial Pump Institute, Zhejiang University of Technology, Hangzhou, Zhejiang 310032, China; 2.China National Institute of Standardization, Beijing 100088, China; 3.Hangzhou Hengli Pump Manufacture Co., Ltd., Hangzhou, Zhejiang 311402, China |
|
|
Abstract The technology development of net positive suction(NPSH) performance indexes about single-stage and single-suction rinsing centrifugal pumps is evaluated.More than 3 000 sample values of performance indexes about vertical and horizontal pumps are collected and compared,and these statistic and neat data are analyzed in detail.Based on these data,it is pointed out that the sample values are inconsistent with measuring ones,performance indexes under low rotating speed are better,and efficiency performance indexes are lower for vertical pumps.centrifugal pump;single-stage and single-suction;efficiency;NPSH
|
Received: 08 August 2013
|
|
|
|
[1] 关醒凡.现代泵技术手册[M].北京:宇航出版社,1995:2-9[2] .GB/T 13006-1991.离心泵、混流泵和轴流泵汽蚀余量[S].[3] .GB/T 13007-1991.离心泵效率[S].[4] .GB/T 3216-1989.离心泵、混流泵、轴流泵和旋涡泵试验方法[S].[5] 丛小青,袁寿其,袁丹青.污水泵的研究现状与发展[J].排灌机械,2005,23(6):1-5[6] 张佩芳,袁寿其,许建强.低比转速离心泵研究现状与发展前景[J].排灌机械,2003,21(6):42-45[7] 卢池,陈次昌,杨昌明.低比转速离心泵内部流场的数值模拟[J].排灌机械,2005,23(6):6-9 |
|
|
|