Analyze on cavitation reason about large reversible tubular pump |
XU Lun-gen1, ZHENG Yuan2, FAN Dao-yu3 |
1.Jiangsu Riverway Management Bureau, Nanjing, Jiangsu 210029, China; 2.Hohai University, Nanjing, Jiangsu 210098, China; 3.Huai′an No.3 Pump Station, Huai′an, Jiangsu 223200, China |
|
|
Abstract To give reference for construction and operation on large reversible tubular pump station,combining with Huai′an No.3 reversible tubular pump,problems on cavitation and its reasons are analyzed through field tests.It demonstrated that the different blade surface cavitation distributed in working surface of blade outlet and inlet;cavitation on outlet(comparing with pumping condition) is more severely than inlet;light cavitation on volute belonged to Ⅲ~Ⅳ.The reason is that deeply consideration on pumping condition is performed in the designing stage,so under higher water head the working conditions are worse and the cavitation appeared.
|
Received: 08 August 2013
|
|
|
|
[1] 沙锡林,陈新方.贯流式水电站[M].北京:中国水利水电出版社,1999:15-30[2] 陈贤源,等.水泵机组的振动分析及故障诊断[J].农业工程学报,1997,3(1):92-96[3] 李继珊.泵站测试技术[M].北京:中国水利水电出版社,1986:6-20[4] .GB 8564-1988.水轮发电机组安装技术规范[S],1998:12-30[5] 王继光.水泵汽蚀危害及抗汽蚀修补措施[J].排灌机械,2004,22(1):33-34[6] 张仁田.贯流式机组在南水北调工程中的应用研究[J].排灌机械,2004,22(5):1-6[7] 肖庆荣.水泵汽蚀的危害及预防[J].排灌机械,2003,21(5):29-30 |
|
|
|