Properly Determine Pumping Station Rebuilding Technical Method By Field-testing Technology |
ZHANG Shu-ping |
City Hydraulic Reconnaissance Survey Design Institute, Yuncheng 044000, China |
|
|
Abstract By instance,discussed by pumping station test technology overall analysis,fined out the problems such as low flux,low efficiency,high energy consume and then by property selecting pump style,turning impeller,adjust vane fix angle,form siphon at out flow pipe so on and so forth different technical method,improved the unit efficiency,realized the purpose of cost reduction and improve the economic returns.
|
Received: 08 August 2013
|
|
|
|
[1] 王万虎.禹门口一级站1#、2#机组技改方案优化研究[J].山西水利科技,2003[2] .GB/T50265-1997.泵站设计规范[S]. |
|
|
|