Technical measure for discontinuous trajectory bucket energy dissipation and sediment prevention at forebay of pumping station |
Gao Chuanchang1, Wang Yuchuan2, Shi Liwen3, Liu Wei3, Yang Hongcun3 |
(1. College of Electric Power, North China University of Water Conservancy and Hydropower, Zhengzhou, Henan 450011, China; 2. State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China; 3. Pingyin Tianshan Electrical Irrigation Agency, Jinan, Shandong 250400, China) |
|
|
Abstract Based on hydraulic flow analysis of forebay and field tests before rehabilitation, the turbulent flow pattern in Tianshan first level pumping station was found, which caused intensive vibration and intermittentvibration of pump units. Then the technical measure of discontinuous trajectory bucket energy dissipation and sediment prevention(DTBED & SPTM), which involves discontinuous bottom baffle sills, discontinuous trajectory bucket piers and two pressure plates, was presented. The experimental results afterrehabilitation show that, with the application of the technical measure, flow patterns of forebay and sump, as well as the pump intake condition are significantly improved, velocity distribution of forebay middle section is uniform and turbulent energy is decreased obviously. The flow rate of single pump, the pump efficiency and device efficiency of pumping station are averagely increased 0.14 m3/s, 4.99% and 3.88%, respectively. The intermittent vibration of pump body is eliminated, and the vibration standard of pump bell mouth intake decreases from intensity stage 4.5to intensity stage 1.8. The sediment depositionof forebay and sump is slowed down, and the sediment removing time is extended from 800 hours before rehabilitation to 1 300 hours after rehabilitation, which proves effective in sediment prevention. The DTBED & SPTM offers a simple yet effective approach to technical rehabilitation of pumping station technological rehabilitation on rivers with high sediment content.
|
Received: 11 June 2010
Published: 30 March 2011
|
|
|
|
[1]Wada A. Flow structure around the intake of a vertical pump[J]. Journal of Thermal Science ,2006,15(2):121-125.[2]Constantinescu G S,Patel V C. Numerical model for simulation of pumpintake flow and vortices[J]. Journal of Hydraulic Engineering ,1998,124(2):123-134.[3]高传昌,曹永梅,刘新阳,等. 田山泵站机组振动原因分析及水力整流措施[J]. 南水北调与水利科技,2010,8(3): 140-141.Gao Chuanchang,Cao Yongmei,Liu Xinyang,et al. Analysis on the cause of unit vibration in Tianshan pump station and hydraulic rectification measures[J]. South-to-North Water Transfers and Water Science & Technology ,2010,8(3): 140-141.(in Chinese)[4]Arboleda G,ElFadel M. Effects of approach flow conditions on pump sump design[J]. Journal of Hydraulic Engineering ,1996,122(9):489-494.[5]刘 超,韩 旭,周济人,等. 泵站侧向进水引河段三维紊流数值模拟[J]. 排灌机械,2009,27(5): 281-285.Liu Chao,Han Xu,Zhou Jiren,et al. Numerical simulation of turbulent flow in forebay with side intake of pumping station[J]. Drainage and Irrigation Machinery ,2009,27(5): 281-285. (in Chinese)[6]陆晓如,佟宏伟,冯建刚. 城市取水泵站进水池进水流态的改善[J]. 排灌机械,2007,25(5): 24-28.Lu Xiaoru,Tong Hongwei,Feng Jiangang. Measures of improving flow patterns for entrance bays of city intake water pumping stations[J]. Drainage and Irrigation Machinery ,2007,25(5): 24-28.(in Chinese)[7]董曾南,章梓雄. 非粘性流体力学[M]. 北京: 清华大学出版社,2003: 343-356.[8]吴持恭. 水力学[M]. 3版. 北京: 高等教育出版社,2003: 301-305.[9]刘新阳,高传昌,石礼文,等. 泵站前池与进水池整流数值模拟[J]. 排灌机械工程学报,2010,28(3):242-246.Liu Xinyang,Gao Chuanchang,Shi Liwen,et al. Numericalsimulation for fluid meliorating in both forebay and suction bay of pumping stations[J]. Journal of Drainage and Irrigation Machinery Engineering ,2010,28(3):242-246.(in Chinese)[10]Moreno M A,Carrion P A,Planells P,et al. Measurement and improvement of the energy efficiency at pumping stations[J]. Biosystems Engineering , 2007,98(4):479-486.[11]MoradiJalal M,Marino M A,Afshar A. Optimal design and operation of irrigation pumping stations[J]. Journal of Irrigation and Drainage Engineering , 2003,129(3):149-154. |
|
|
|