Impeller diameter maximum approach for deep well pumps |
LU Wei-gang, ZHANG Qi-hua, SHI Wei-dong |
Technical and Research Center of Fluid Machinery Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China |
|
|
Abstract The impeller diameter maximum approach has been developed to solve the problem that deep well pump diameter was restricted by the well diameter.The approach extends the front shroud to the inner wall,which maximizes the impeller diameter under the same sized well condition.The return guide vane is used to minimize the pump axial length.So the single stage head is enlarged by 50% and the cost is reduced by 30%.The method and its details are introduced.By using CFD and model tests,it is confirmed that this approach can increase both pump head and efficiency.
|
Received: 08 August 2013
|
|
|
|
[1] 关醒凡.现代泵技术手册[M].北京:宇航出版社,1995[2] 袁寿其.低比速离心泵理论与设计[M].北京:机械工业出版社,2001[3] 袁秀文,岳文法.离心式潜水泵水力模型试验研究[J].农业机械学报,1980,11(2):51-59[4] 刘在伦,刑乐斌,朱亮.潜水泵设计时值得注意的几个问题[J].排灌机械,2003,21(2):12-14[5] 薛枫.基于PCAD2000的井用潜水电泵水力设计[J].排灌机械,2003,21(3):10-12[6] .JB/T 3564-1992.长轴离心深井泵型式与基本参数[S].[7] .GB/T 2816-1991.井用潜水泵型式和基本参数[S].[8] .GB/T 2816-2002.井用潜水泵[S].[9] 陆伟刚,施卫东,王准.井泵新系列研究与探讨[J].中国农村水利水电,2006(3):49-51[10] 陆伟刚,刘向东.离心泵最大轴功率的准确预算[J].江苏理工大学学报(自然科学版),1995,16(zk):57-63 |
|
|
|