Measurement of faint vibration signal in water pump |
HU Chi-bing, ZAHNG Ling, WANG Xiao-yun |
College of Mechano-Electronic Engineering, Lanzhou Univ.of Tech., Lanzhou, Gansu 730050, China |
|
|
Abstract Noise is the biggest obstacle that makes the incipient fault diagnosis results uncorrected.Using the wavelet transform,the noise of water pump is decomposed in many scales.And then be fileted according to the correlations of wavelet coefficients in close layer.By selecting the process parameters adaptively,WTDCF can de-noise signal efficiently.More important,the faint component in the signal will become stronger compared with the noise component.According to the analysis of the fault signal in water pump,results show that WTDCF method is effective for water pump incipient fault diagnosis.
|
Received: 08 August 2013
|
|
|
|
[1] 郑颖玲.排水泵站设备振动测试及分析[J].给水排水,2003,11(5):78-79[2] 廖霞,陈平,张国珍.小波变换在水泵故障诊断中的应用[J].西南农业大学学报(自然科学版),2001,23(5):478-480[3] 徐晨,赵瑞珍,甘晓冰.小波分析·应用算法[M].北京:科学出版社,2004:101-103[4] 孙延奎.小波分析及其应用[M].北京:机械工业出版社,2005:157-159 |
|
|
|