Analysing Temperature Ascend of Submerible Electric Motor |
XUE Feng |
Inner Mongolia Wuhai Wuhu Pump liability Company, Wuhai, The Inne r Mongolia Autonomous Region 016000, China |
|
|
Abstract As heat exchange and disseminating heat of manners of Submerible Electric motor are complex, analogy means are adopted in calculating temperature ascend of sub merible electric motor. But analogy means of precision was relatively low and di seconomy. So we adopted predigest heat way in calculating temperature ascend of submerible electric motor. We proved that way was veracity and could completely substitute analogy means.
|
Received: 07 August 2013
|
|
|
|
[1] 胡志强.潜油电机温升计算[J].电机技术,1993,53(2):15-17[2] 郑砥中.潜油电机计算特点及表面散热计算[J].电机技术,1994,57(2):16[3] 陆夫昌.中小型外冷定子绕组温升计算程序[J].电机技术,1988,34(3):6 |
|
|
|