Abstract This atricle analyzed the malfunction in the Fenghuangjing Pumping Station, whic h was caused by the fluctuation pressure intensity error in outlet. By spacing o ut the vibration source,we solved this problem. According to the operation, it i s proved that this method is casy and reasonable. This method gets the desired e ffect making the pumping axis working stable, resulting in district economical a nd social benefits.
|
Received: 07 August 2013
|
|
|
|
[1] .SD 204--1986.泵站技术规范,安装分册,技术管理分册[S],1987-11-01:11-12,43[2] 安徽省巢湖行署.安徽省巢湖项目引用外资可行性研究报告[M],1984,9:68[3] 安徽省水利水电勘测设计院.巢湖流域防洪规划报告[R],1984,4:10[4] 日本农业土木事业协会,丘传忻,林中卉.泵站工程技术手册[M].北京:中国农业出版社,1998:55-57[5] 安徽省水利部淮委水利科学研究所.凤凰颈排灌站自流排灌运行水工模型试验报告[M],1991,1:24-28 |
|
|
|