Studies on the XMB Diaphragm Pump Performance parameter Measuring System |
MA Ming jian, WANG Zun yuan, GUO Zhi dong, YIN Feng fu |
Department of Agricultural Engineering, Shandong Institute of Technology, Zibo Shandong 255012 China |
|
|
Abstract It introduces how to measure and deal with the performance parameter about the flow rate, pressure, speed and torque of piston diaphragm pump. It also shows calibration of system sensor and anti interference measures and the hardware of measuring system is based on PC. Object language Delphi for Windows is adopted in the system software. Both fictitious instrument and modularization design ideals are used for programming. Experiment results disclose fine reliability, simple structure and exact measuring so it reaches the national standard GB7784—87.
|
Received: 07 August 2013
|
|
|
|
[1] 中国标准出版社总编室.中国国家标准汇编[S].北京:中国标准出版社,1992:255-279[2] 沈兰荪.数据采集技术[M].合肥:中国科学技术大学出版社,1990:225[3] 肖冬荣.微型计算机实时控制系统的抗干扰技术[M].武汉:湖北科学技术出版社,1985:10-121 |
|
|
|