Abstract:Aiming at the problem of vibration in vertical asynchronous motor in circulating supply-water pump station,which set in the Second Electrical Power Company Limited of Yangzhou,some reason are analyzed,such as installation,inspection and manufacture.The conclusion is obtained that the vibration is electromagnetic vibration by spectrum analysis.The vibration is fade to 0.01mm by adding 3 equalizing cable on the stator coil.
钱利华. 电厂循环供水泵站立式异步电动机振动分析[J]. 排灌机械工程学报, 2006, 24(2): 31-32.
QIAN Li-hua. Analysis of Vibration in Vertical Asynchronous Motor in Circulating Supply-Water Pump Station. Journal of Drainage and Irrigation Machinery Engin, 2006, 24(2): 31-32.