Achievements and Analysis of Pump Model Unit Test for the Pump Station in the East Line of the Project of South-to-North Water Transfers
GUAN Xing-fan, WU Jie, ZHU Quan-rong
Jiangsu University, Zhenjiang, Jiangsu 212013; The Design Academy of Huaihe River Water Conservancy Commission, Bengbu, Anhui 233001; Wuxi Pump Manufacturing Company Limited, Wuxi, Jiangsu 214023, China
Abstract:The achievements of unit test of pump models in pump stations of Wannian Xia, Jietai, Liushan, Taier Zhuang et al. were presented. The analysis results of them and their tests on single pumps show that, there are great difference between them, the blade angle on the best efficient point is larger by 2%-4%, and the efficiency of single pump is higher than that of pump unit by 8%-10%, and the water head of pump unit with the best efficiency approximately equal to those of single pumps, and with the scope of ?5%.These difference have not been grasped qualitatively, in this case, choosing pump according to the test results of pump units is better than that of single pump, which can improve the reliability.
关醒凡;伍杰;朱泉荣. 南水北调东线已招标泵站水泵模型装置试验成果及分析[J]. 排灌机械工程学报, 2006, 24(1): 1-7.
GUAN Xing-fan, WU Jie, ZHU Quan-rong. Achievements and Analysis of Pump Model Unit Test for the Pump Station in the East Line of the Project of South-to-North Water Transfers. Journal of Drainage and Irrigation Machinery Engin, 2006, 24(1): 1-7.