Abstract:The reliability analysis of pump station and water gate under earthquake force is rare because of the condition of hydraulic structure and structural complexity. The method considering the earthquake force in the calculation of reliability indexes based on reliability theory is put forward. The reliability of pump station by example is analyzed.
李晓丽;申向东;解卫东. 地震载荷作用下泵房可靠度分析[J]. 排灌机械工程学报, 2003, 21(5): 15-18.
LI Xiao-li, SHEN Xiang-dong, XIE Wei-dong. Reliability Analysis of Pump Station on Earthouart Force. Journal of Drainage and Irrigation Machinery Engin, 2003, 21(5): 15-18.